SPOT AR1901

Note: Please note that the current price for this product does not include shipping fees. After ordering, kindly contact your sales manager/Customer Service Robot or email (sales@bitmain.com) to confirm your shipping method and obtain the final shipping cost.

Function
BTC/BCH/BSV SHA256 Hydro-cooling Miner
Specifications
1172T|24KW|4 Standard Hydro-cooling ANTMINER
Price
7,576 $/Package
Shipping Date
SPOT Shipping in 20 working days after fully paid
Payment Method

USD | BTC | ETC | USDC(ERC20) | USDT(ERC20/TRC20)

SPOT AR1901

$7,576.00

| Specifications for ANTRACK V2-EC2-DT

Product GlanceValue
ModelANTRACK V2-EC2-DT
VersionV2-EC2-DT
Capacity4 units ANTMINER (Hydro) or
4 units ANTMINER (U2 Hydro) or
2 units ANTMINER (U3 Hydro) 
Maximum load,kW24
Detailed CharacteristicsValue
Part 1: Mining Cabinet 
Hardware Configuration 

Size (Length*Width*Height), mm (without package)

1200*600*1200

Size (Length*Width*Height), mm (with package)

1320*710*1340

Net weight, kg (without package)

120

Gross weight, kg (with package)

195

Network connection mode

RJ45 Ethernet 10/100M

Power Supply 
Power supply AC Input voltage, Volt(1-1)380~415V AC
Power supply AC Input Frequency Range, Hz50~60
Power supply AC Input current, Amp(1-2)63
Water pump 

Rated power, W

450

Noise, dBA@1m

60
Lift, m19
Size (Length*Width* Height), mm360*210*268
Part 2: External Cooler(1-3) 
Hardware Configuration 

Size (Length*Width*Height), mm (without package)

1200*650*1180

Size (Length*Width*Height), mm (with package)

1320*710*1340

Net weight, kg (without package)

90

Gross weight, kg (with package)

160

Power supply 
Power supply AC input voltage, Volt(1-1)380~415V AC
Power supply AC input frequency range, Hz50~60
Maximum power supply AC input current, Amp(1-2)63
Fan 

Rated power, W

750

Noise, dBA@1m

64

Size (Length*Height*Thickness), mm

850*850*305

Environment Requirements 

Ambient temperature, °C

-20~40

Water flow, L/min

32.0~40.0

Water pressure, bar

≤3.5

Working fluid(1-4)

Antifreeze (10%)

Installation distance, m(1-5)

5

Liquid PH

7.8~8.5

Storage temperature, °C

-20~70

Operation humidity(non-condensing), RH

10~90%

Notes:

(1-1) Caution: Wrong input voltage may cause server damaged.

(1-2) Three-phase AC input.

(1-3) The External cooler should be placed outdoors in a well-ventilated environment.

(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

(1-5) The distance between mining cabinet and external cooler.

| Specifications for S19 XP+ Hyd.

Product GlanceValue
ModelS19 XP+ Hyd.
Crypto algorithm/coinsSHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(2-1)279
Power on wall @35°C(2-2)Watt(2-1)5,301
Power efficiency on wall @35°C(2-2)J/TH(2-1)19
Detailed CharacteristicsValue
Power Supply 
Phase3
Input voltage, Volt(3-1)380~415
Input Frequency Range, Hz50~60
Input max current, Amp12
Hardware Configuration 
Networking connection modeRJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o package), mm339*173*207
Server Size (Length*Width*Height, with package), mm570*316*430
Net weight, kg12.3
Gross weight, kg13.6
Environment Requirements 
Inlet coolant temperature,°C
20~50
Coolant flow, L/min
8.0~10.0
Coolant pressure, bar
≤3.5
Working coolant(3-2)
Antifreeze/ Pure water/Deionized water
Coolant pH value
Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized water:8.5~9.5
Diameter of coolant pipe connector, mm
OD10
Storage temperature,°C-20~70
Operation humidity(non-condensing) , RH10~90%

Notes:

(2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.

(2-2) Inlet coolant temperature.

(3-1) Caution: Wrong input voltage may cause server damaged.

(3-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Hydro Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!

| Purchasing Guidelines

1. The ANTRACK is recommended to be used simultaneously with the Hydro-cooling ANTMINERS.

2. The pictures shown are for reference only; the final shipment version shall prevail.

3. Contact Customer Service Robot to review the shipping cost.

4. After an order has been submitted, a request to cancel the order, refund any part of the ordered amount or change the ordered item(s) to different item(s) or different batch(es) will not be entertained by BITMAIN.

| Shipping Details

1. Shipments will be scheduled on a first-paid-first-ship basis for orders on which BITMAIN has received full payment.

2. You are responsible for any customs delays or returned shipments due to a lack of proper documentation. It’s highly recommended to be aware of local customs clearance policies and prepare all customs documentation ahead of time to avoid delays or unexpected costs.

3. Click here to download Certificates of Conformity and find additional information on customs clearance for BITMAIN products.

| Warranty

1. A 365-day warranty period is provided starting from the shipping date. BITMAIN will cover shipping costs when shipping a replacement unit within the warranty period.

2. The warranty only applies to the original purchaser who purchased the machine directly from BITMAIN. Once the miner is resold, warranty coverage becomes the responsibility of the re-seller.

3. If the user fails to use the product per the given instructions, specifications, and conditions provided or changes the function settings of the unit without BITMAIN’s prior consent, BITMAIN will not be liable for any damage arising therefrom.

4. Click here for a complete list of the Terms & Conditions that apply to all orders placed on https://shop.bitmain.com.